U.S. flag An official website of the United States government
  1. Home
  2. Medical Devices
  3. Science and Research | Medical Devices
  4. Medical Device Regulatory Science Research Programs Conducted by OSEL
  5. Artificial Intelligence and Machine Learning Program: Research on AI/ML-Based Medical Devices
  1. Medical Device Regulatory Science Research Programs Conducted by OSEL

Artificial Intelligence and Machine Learning Program: Research on AI/ML-Based Medical Devices

The Artificial Intelligence and Machine Learning (AI/ML) Program in the FDA’s Center for Devices and Radiological Health (CDRH) conducts regulatory science research to ensure patient access to safe and effective medical devices using AI/ML. This is one of 20 research programs in CDRH’s Office of Science and Engineering Laboratories (OSEL).

Artificial Intelligence, Machine Learning, and Medical Devices

The growth of commercial AI/ML-based technologies has shown a spillover of AI/ML for use as and within medical devices, with important contributions in application areas such as:

  • Image acquisition and processing
  • Earlier disease detection
  • More accurate diagnosis, prognosis, and risk assessment
  • New patterns identification on human physiology
  • Personalized diagnostics and therapeutics.

Challenges in developing robust clinical and non-clinical evaluation methods and in better understanding the effects of AI/ML devices in the real world stem from factors such as:

  • The rapid application of AI/ML technology
  • The unique nature of clinical medical data (for example, low prevalence of disease, lack of or difficulty in obtaining truth data, and so forth).

In addition, the ability of AI/ML for continuous learning presents unique regulatory challenges with a need to develop appropriate regulatory controls and test methods to balance the potential benefits of AI/ML adaption with the risks of a limited assessment paradigm.

Regulatory Science Gaps and Challenges

Major regulatory science gaps and challenges that drive the Artificial Intelligence and Machine Learning Program are:

  • Lack of methods that can enhance AI/ML algorithm training for clinical datasets that are typically much smaller than non-clinical datasets.
  • Lack of clear definition or understanding of artifacts, limitations, and failure modes for fast-growing applications of Deep-Learning (DL) algorithms in the denoising and reconstruction of medical images.
  • Lack of a clear reference standard for assessing accuracy of AI/ML-based Quantitative Imaging (QI) and radiomics tools.
  • Lack of assessment techniques to evaluate the trustworthiness of adaptive and autonomous AI/ML devices (for example, continuously learning algorithms).
  • Lack of systematic approaches to address the robustness of various AI/ML input factors, such as data acquisition factors, patient demographics, and disease factors, to patient outcomes in a regulatory submission.

The Artificial Intelligence and Machine Learning Program is intended to fill these knowledge gaps by developing robust AI/ML test methods and evaluating test methodologies for assessing AI/ML performance both in premarket and real-world settings to reasonably ensure the safety and effectiveness of novel AI/ML algorithms.

Artificial Intelligence and Machine Learning Program Activities

The Artificial Intelligence and Machine Learning Program focuses on regulatory science research in these areas:

  • Data augmentation, transferring learning, and other novel approaches to enhance AI/ML training/testing for small clinical datasets.
  • Study design and analysis methods for AI/ML-based computer-aided triage (CADt).
  • Non-clinical phantoms and test methods for assessing specific imaging performance claims for DL-based denoising and image reconstruction algorithms.
  • Imaging phantoms and computational models to support QI and radiomics assessment.
  • Assessment techniques for evaluating the reliability of adaptive AI/ML algorithms to support non-clinical test method development.
  • Assessment approaches to estimate and report the robustness of AI/ML to variation in data acquisition factors.

For more information, email OSEL_AIML@fda.hhs.gov

Subscribe to CDRH Science

Receive updates on regulatory science, the science of developing new tools, standards and approaches to assess the safety, efficacy, quality, and performance of medical devices and radiation-emitting products.

Back to Top