  5. Artificial Intelligence and Machine Learning Program: Research on AI/ML-Based Medical Devices
  1. Medical Device Regulatory Science Research Programs Conducted by OSEL

Artificial Intelligence and Machine Learning Program: Research on AI/ML-Based Medical Devices

The Artificial Intelligence and Machine Learning (AI/ML) Program in the FDA’s Center for Devices and Radiological Health (CDRH) conducts regulatory science research to ensure patient access to safe and effective medical devices using AI/ML. This is one of 20 research programs in CDRH’s Office of Science and Engineering Laboratories (OSEL).

Artificial Intelligence, Machine Learning, and Medical Devices

The growth of commercial AI/ML-based technologies has shown a spillover of AI/ML for use as and within medical devices, with important contributions in application areas such as:

  • Image acquisition and processing
  • Earlier disease detection
  • More accurate diagnosis, prognosis, and risk assessment
  • New patterns identification on human physiology
  • Personalized diagnostics and therapeutics.

Challenges in developing robust clinical and non-clinical evaluation methods and in better understanding the effects of AI/ML devices in the real world stem from factors such as:

  • The rapid application of AI/ML technology
  • The unique nature of clinical medical data (for example, low prevalence of disease, lack of or difficulty in obtaining truth data, and so forth).

In addition, the ability of AI/ML for continuous learning presents unique regulatory challenges with a need to develop appropriate regulatory controls and test methods to balance the potential benefits of AI/ML adaption with the risks of a limited assessment paradigm.

Regulatory Science Gaps and Challenges

Major regulatory science gaps and challenges that drive the Artificial Intelligence and Machine Learning Program are:

  • Lack of methods that can enhance AI/ML algorithm training for clinical datasets that are typically much smaller than non-clinical datasets.
  • Lack of clear definition or understanding of artifacts, limitations, and failure modes for fast-growing applications of Deep-Learning (DL) algorithms in the denoising and reconstruction of medical images.
  • Lack of a clear reference standard for assessing accuracy of AI/ML-based Quantitative Imaging (QI) and radiomics tools.
  • Lack of assessment techniques to evaluate the trustworthiness of adaptive and autonomous AI/ML devices (for example, continuously learning algorithms).
  • Lack of systematic approaches to address the robustness of various AI/ML input factors, such as data acquisition factors, patient demographics, and disease factors, to patient outcomes in a regulatory submission.

The Artificial Intelligence and Machine Learning Program is intended to fill these knowledge gaps by developing robust AI/ML test methods and evaluating test methodologies for assessing AI/ML performance both in premarket and real-world settings to reasonably ensure the safety and effectiveness of novel AI/ML algorithms.

Artificial Intelligence and Machine Learning Program Activities

The Artificial Intelligence and Machine Learning Program focuses on regulatory science research in these areas:

  • Data augmentation, transferring learning, and other novel approaches to enhance AI/ML training/testing for small clinical datasets.
  • Study design and analysis methods for AI/ML-based computer-aided triage (CADt).
  • Non-clinical phantoms and test methods for assessing specific imaging performance claims for DL-based denoising and image reconstruction algorithms.
  • Imaging phantoms and computational models to support QI and radiomics assessment.
  • Assessment techniques for evaluating the reliability of adaptive AI/ML algorithms to support non-clinical test method development.
  • Assessment approaches to estimate and report the robustness of AI/ML to variation in data acquisition factors.