WARNING LETTER
Buffalo Pharmacies Inc. dba Swan Prescription Center MARCS-CMS 539769 —
- Delivery Method:
- UPS
- Recipient:
-
Recipient NameMr. Alec Gillies
- Buffalo Pharmacies Inc. dba Swan Prescription Center
1479 Kensington Avenue
Buffalo, NY 14215-1436
United States
- Issuing Office:
- New Jersey District Office
United States
Division of Pharmaceutical Quality Operations I 10 Waterview Blvd, 3rd FL Parsippany, NJ 07054 Telephone: (973) 331-4900 FAX: (973) 331-4969 | |
WARNING LETTER
CMS 539769
December 13, 2017
VIA UPS NEXT DAY AIR
Mr. Alec Gillies, General Manager
Buffalo Pharmacies, Inc. DBA Swan Prescription Center
1479 Kensington Avenue
Buffalo, NY 14215-1436
Dear Mr. Gillies:
From June 20, 2017, to June 23, 2017, U.S. Food and Drug Administration (FDA) investigators inspected your facility, Buffalo Pharmacies, Inc., DBA Swan Prescription Center, located at 6035 Transit Road, East Amherst, NY 14051-1803. During the inspection, the investigators noted that drug products you produced failed to meet the conditions of section 503A of the Federal Food, Drug, and Cosmetic Act (FDCA) [21 U.S.C. § 353a] for exemption from certain provisions of the FDCA. In addition, the investigators noted serious deficiencies in your practices for producing sterile drug products, which put patients at risk.
FDA issued a Form FDA 483 to your firm on June 23, 2017. Based on this inspection, it appears that you produced drug products that violate the FDCA.
A. Compounded Drug Products Under the FDCA
Section 503A of the FDCA describes the conditions under which human drug products compounded by a licensed pharmacist in a State licensed pharmacy or a Federal facility, or a licensed physician, qualify for exemptions from three sections of the FDCA: compliance with current good manufacturing practices (CGMP) (section 501(a)(2)(B)); labeling with adequate directions for use (section 502(f)(1)); and FDA approval prior to marketing (section 505) [21 U.S.C. §§ 351(a)(2)(B), 352(f)(1) and 355(a)].1 Receipt of valid prescriptions for individually-identified patients is one of the conditions for the exemptions under section 503A.
B. Failure to Meet the Conditions of Section 503A
During the inspection, the FDA investigators noted that drug products produced by your firm failed to meet the conditions of section 503A. For example, the investigators noted that your firm did not receive valid prescriptions for individually-identified patients for a portion of the drug products you produced.
Therefore, you compounded drug products that do not meet the conditions of section 503A and are not eligible for the exemptions in that section from the FDA approval requirement of section 505 of the FDCA, the requirement under section 502(f)(1) of the FDCA that labeling bear adequate directions for use, and the requirement of compliance with CGMP under section 501(a)(2)(B) of the FDCA. In the remainder of this letter, we refer to your drug products that do not qualify for exemptions under section 503A as the “ineligible drug products.”
Specific violations are described below.
C. Violations of the FDCA
Adulterated Drug Products
The FDA investigators noted that drug products intended or expected to be sterile were prepared, packed, or held under insanitary conditions, whereby they may have become contaminated with filth or rendered injurious to health, causing your drug products to be adulterated under section 501(a)(2)(A) of the FDCA. For example:
1. Your firm did not use a sporicidal agent or sterile wipes, and used a non-sterile disinfectant as part of your disinfection program for the aseptic processing area.
2. Your firm failed to conduct media fills to simulate aseptic operations.
3. The investigators observed an operator’s bare hands being exposed within the ISO 5 work area while donning sterile gloves in preparation for sterile drug production.
4. Your firm did not conduct viable or non-viable monitoring under dynamic conditions within the ISO 5 area.
5. Your firm failed to demonstrate through appropriate studies that your hood is able to provide adequate protection of the ISO 5 area in which sterile products are processed. Therefore, your products may be produced in an environment that poses a significant contamination risk.
Furthermore, the manufacture of the ineligible drug products is subject to FDA’s CGMP regulations, Title 21, Code of Federal Regulations (CFR), parts 210 and 211. The FDA investigators observed significant CGMP violations at your facility, causing the ineligible drug products to be adulterated within the meaning of section 501(a)(2)(B) of the FDCA. The violations included, for example:
1. Your firm failed to establish an adequate system for cleaning and disinfecting the room and equipment to produce aseptic conditions (21 CFR 211.42(c)(10)(v)).
2. Your firm failed to establish and follow appropriate written procedures that are designed to prevent microbiological contamination of drug products purporting to be sterile, and that include validation of all aseptic and sterilization processes (21 CFR 211.113(b)).
3. Your firm failed to establish an adequate system for monitoring environmental conditions in aseptic processing areas (21 CFR 211.42(c)(10)(iv)).
4. Your firm failed to establish an adequate air supply filtered through high-efficiency particulate air filters under positive pressure in the aseptic processing areas (21 CFR 211.42(c)(10)(iii)).
Under section 301(a) of the FDCA [21 U.S.C. § 331(a)], the introduction or delivery for introduction into interstate commerce of any drug that is adulterated is a prohibited act. Further, it is a prohibited act under section 301(k) of the FDCA [21 U.S.C. § 331(k)] to do any act with respect to a drug, if such act is done while the drug is held for sale after shipment in interstate commerce and results in the drug being adulterated.
Unapproved New Drug Products
You do not have any FDA-approved applications on file for the ineligible drug products that you compounded.2 Under sections 505(a) and 301(d) of the FDCA [21 U.S.C. § 331(d)], a new drug may not be introduced into or delivered for introduction into interstate commerce unless an application approved by FDA under section 505 of the FDCA is in effect for the drug. Marketing of these products, or other applicable products, without an approved application violates these provisions of the FDCA.
Misbranded Drug Products
The ineligible drug products you compounded are intended for conditions not amenable to self-diagnosis and treatment by individuals who are not medical practitioners; therefore, adequate directions for use cannot be written so that a layman can use these products safely for their intended uses. Consequently, their labeling fails to bear adequate directions for their intended uses.3 Accordingly, these ineligible drug products are misbranded under section 502(f)(1) of the FDCA. The introduction or delivery for introduction into interstate commerce of these products therefore violates section 301(a) of the FDCA. It is also a prohibited act under section 301(k) of the FDCA to do any act with respect to a drug, if such act is done while the drug is held for sale after shipment in interstate commerce and results in the drug being misbranded.
D. Corrective Actions
Your firm did not submit a response to the observations cited on the Form FDA 483 issued at the close of the inspection. As a result, we are unable to evaluate the adequacy of the corrective actions you may have taken.
Regarding issues related to the conditions of Section 503A, we acknowledge your memo dated June 23, 2017, which states that “effective immediately, Buffalo Pharmacies employees will not produce any prescriptions that are intended for office use”.
Should you continue to compound and distribute drug products that do not meet the conditions of section 503A, the compounding and distribution of such drugs would be subject to the new drug approval requirement, the requirement to label drug products with adequate directions for use, and the drug CGMP regulations. Before doing so, you must comply with the requirements of section 505 and 502(f)(1) and fully implement corrections that meet the minimum requirements of the CGMP regulations.4
In addition to the issues discussed above, you should note that CGMP require the implementation of quality oversight and controls over the manufacture of drugs, including the safety of raw materials, materials used in drug manufacturing, and finished drug products. See section 501 of the FDCA. If you choose to contract with a laboratory to perform some functions required by CGMP regulations, it is essential that you select a qualified contractor and that you maintain sufficient oversight of the contractor’s operations to ensure that it is fully CGMP compliant. Regardless of whether you rely on a contract facility, you are responsible for assuring that drugs you produce are neither adulterated nor misbranded. [See 21 CFR 210.1(b), 21 CFR 200.10(b)].
FDA strongly recommends that your management undertake a comprehensive assessment of operations, including facility design, procedures, personnel, processes, maintenance, materials, and systems. In particular, this review should assess your aseptic processing operations. A third party consultant with relevant sterile drug processing expertise should assist you in conducting this comprehensive evaluation.
E. Conclusion
The violations cited in this letter are not intended to be an all-inclusive statement of violations at your facility. You are responsible for investigating and determining the causes of the violations identified above and for preventing their recurrence or the occurrence of other violations. It is your responsibility to ensure that your firm complies with all requirements of federal law, including FDA regulations.
You should take prompt action to correct the violations cited in this letter. Failure to promptly correct these violations may result in legal action without further notice, including, without limitation, seizure and injunction.
Within fifteen (15) working days of receipt of this letter, please notify this office in writing of the specific steps that you have taken to correct the violations. Please include an explanation of each step being taken to prevent the recurrence of the violations, as well as copies of related documentation. If you do not believe that the products discussed above are in violation of the FDCA, include your reasoning and any supporting information for our consideration. If you cannot complete corrective action within fifteen (15) working days, state the reason for the delay and the time within which you will complete the correction.
Your written notification should refer to Warning Letter # 539769. Please address your reply to:
Liatte Krueger
Compliance Officer/OPQ Division 1
New Jersey District Office
10 Waterview Blvd., 3rd Floor
Parsippany, NJ 07054
If you have questions regarding the contents of this letter, please contact CDR Liatte Krueger via email at [email protected] or phone at (973) 331-4933.
Sincerely,
/S/
Diana Amador-Toro
Division Director/OPQ Division 1
New Jersey District Office
________________________________________
1 We remind you that there are conditions other than those discussed in this letter that must be satisfied to qualify for the exemptions in section 503A of the FDCA.
2 The specific products made by your firm are drugs within the meaning of section 201(g) of the Act, [21 U.S.C. § 321(g)] because they are intended for use in the diagnosis, cure, mitigation, treatment, or prevention of diseases and/or because they are intended to affect the structure or any function of the body. Further, they are “new drugs” within the meaning of section 201(p) [21 U.S.C. 321(p)] of the FDCA because they are not generally recognized as safe and effective for their labeled uses.
3 Your ineligible drug products are not exempted from the requirements of section 502(f)(1) of the FDCA by regulations issued by the FDA (see, e.g., 21 CFR 201.115).
4 In this letter, we do not address whether your proposed corrective actions would resolve the CGMP violations noted above.