Equivalent Testing Methodology for Agricultural Water
Print & Share (PDF: 152KB)
Imprimir y compartir En Español (Spanish)
FDA has determined that the following quantification methods are scientifically valid and at least equivalent to the method of analysis in § 112.151(a), “Method 1603: Escherichia coli (E. coli) in Water by Membrane Filtration Using Modified membrane-Thermotolerant Escherichia coli Agar (Modified mTEC)” (December 2009), in accuracy, precision, and sensitivity in quantifying generic Escherichia coli in agricultural water when used in connection with the criteria described in § 112.44(a) or § 112.44(b).
- Method 1603: Escherichia coli (E. coli) in Water by Membrane Filtration Using Modified membrane-Thermotolerant Escherichia coli Agar (Modified mTEC) (September 2014). U.S. Environmental Protection Agency. EPA-821-R-14-010.
- Method 1103.1: Escherichia coli (E. coli) in Water by Membrane Filtration Using membrane-Thermotolerant Escherichia coli Agar (mTEC) (March 2010). U.S. Environmental Protection Agency. EPA-821-R-10-002.
- Method 1604: Total Coliforms and Escherichia coli in Water by Membrane Filtration Using a Simultaneous Detection Technique (MI Medium) (September 2002). U.S. Environmental Protection Agency. EPA-821-R-02-024.
- 9213 D – Natural Bathing Beaches (2007). In: Standard Methods for the Examination of Water and Wastewater, 22nd Edition (Rice E.W., et al., Ed.), 9-46 – 9-48. Washington, DC: American Public Health Association. (2012).
- 9222 B – Standard Total Coliform Membrane Filter Procedure (1997), followed by 9222 G – MF Partition Procedures (1997) using NA-MUG media. In: Standard Methods for the Examination of Water and Wastewater, 21st Edition (Eaton A.D., et al., Ed.), 9-60 – 9-65, and 9-70 – 9-71, respectively. Washington, DC: American Public Health Association. (2005).
- D 5392-93 – Standard Test Method for Isolation and Enumeration of Escherichia coli in Water by the Two-Step Membrane Filter Procedure. In: Annual Book of ASTM Standards, Volume 11.02. ASTM International. (1996, 1999, 2000).
- Hach Method 10029 for Coliforms – Total and E. coli, using m-ColiBlue24 Broth PourRite Ampules.
- IDEXX Colilert Test Kit, but only if using IDEXX Quanti-Tray/2000 for quantification.
- IDEXX Colilert-18 Test Kit, but only if using IDEXX Quanti-Tray/2000 for quantification.
With regard to criteria described only in § 112.44(a), FDA has determined that the following presence/absence methods are scientifically valid and at least equivalent to the method of analysis in § 112.151(a), “Method 1603: Escherichia coli (E. coli) in Water by Membrane Filtration Using Modified membrane-Thermotolerant Escherichia coli Agar (Modified mTEC)” (December 2009), in accuracy, precision, and sensitivity in detecting generic Escherichia coli in agricultural water.
- TECTATM EC/TC medium and the TECTATM Instrument: A Presence/Absence Method for the Simultaneous Detection of Total Coliforms and Escherichia coli (E. coli) in Drinking Water. (2014).
- Modified ColitagTM Test Method for the Simultaneous Detection of E. coli and other Total Coliforms in Water. ATP D05-0035. (2009).
- IDEXX Colilert Test Kit
- IDEXX Colilert-18 Test Kit
- IDEXX Colisure Test Kit
- E*Colite Bag or Vial Test for Total Coliforms and E. coli in Potable Water. Charm Sciences, Inc.
- 101298 Readycult Coliforms 100. EMD Millipore (division of Merck KGaA, Darmstadt, Germany).