Coding Resources for Medical Device Reports
This page contains a comprehensive set of resources for reporters to use when selecting event codes in a Medical Device Report (MDR). It contains information about the codes and the MedWatch Medical Device Reporting Code Instructions, sometimes referred to as the coding manual.
Current MDR Adverse Event Codes
The FDA MDR adverse event codes are divided into seven code types. The list below contains a link to the hierarchy for each code type, which lists all active codes of that type and their relationships.
Code Type | Hierarchy |
---|---|
Medical Device Problem | Annex A |
Medical Device Component | Annex G |
Cause Investigation - Type of Investigation | Annex B |
Cause Investigation - Investigation Findings | Annex C |
Cause Investigation - Investigation Conclusion | Annex D |
Health Effects - Clinical Signs and Symptoms or Conditions | Annex E |
Health Effects - Health Impact | Annex F |
Reporters should read and familiarize themselves with the hierarchies above before filing an MDR.
Updates
The list below contains summaries of updates to the FDA MDR adverse event codes.
August 30, 2023 Update: IMDRF 2023 Maintenance
- Annex A: Added 4 new terms (A2501, A0514, A050408, A0723), modified 4 terms (A050405, A07, A14, A1412), and retired 1 term (A071205).
- Annex B: Added 1 new term (B25) and modified 3 terms (B15, B16, B24).
- Annex C: Added 6 new terms (C0109, C0210, C0708, C2301, C2302, C24) and modified 2 terms (C1302, C160504).
- Annex D: Added 2 new terms (D20, D21).
- Annex E: Added 19 new terms (E0209, E0520, E0624, E0625, E0626, E0627, E0854, E0855, E0856, E0857, E1212, E1312, E1313, E1314, E1419, E1420, E1727, E2124, E2343) and modified 13 terms (E040202, E0607, E0824, E0827, E0845, E090801, E090802, E120501, E1308, E2012, E2302, E2322, E2401). Updated NCI mapping for 3 terms (E040202, E1308, E2302).
- Annex F: Added 1 new term (F2307) and modified 5 terms (F11, F19, F1907, F2202, F24). Updated NCIt mapping for 1 term (F2202).
- Annex G: Added 4 new terms (G0200804, G03014, G03015, G03016) and modified 2 terms (G0200401, G04097). Updated NCIt mapping for 1 term (G04115).
August 19, 2022 Update: IMDRF 2022 Maintenance
- Annex A: Added 9 terms (A0105, A0106, A020603, A050406, A050407, A050705, A050901, A090814, A210106) and modified 6 terms (A020601, A0504, A050401, A050402, A110201, A2302).
- Annex B: Added 1 new term (B24) and modified 1 term (B05).
- Annex C: Added 2 new terms (C1010, C1011).
- Annex D: Added 2 new terms (D1108, D19).
- Annex E: Added 65 new terms (E012208, E012209, E0140, E0141, E0142, E0143, E014301, E014302, E0207, E0208, E0311, E0312, E0313, E050102, E0519, E0753, E083804, E083903, E0845, E0846, E0847, E0848, E0849, E0850, E0851, E0852, E0853, E0907, E0908, E090801, E090802, E0909, E0910, E1034, E1035, E1108, E1109, E120203, E120204, E120205, E120206, E120207, E120208, E120209, E1418, E1520, E1636, E1637, E1638, E1639, E1640, E1641, E171602, E171603, E1724, E1725, E1726, E1805, E2121, E2122, E2123, E2205, E2206, E2207, E233802) and modified 11 terms (E0309, E0506, E2337, E082901, E1025, E120501, E1618, E1621, E1625, E180102, E2103). Updated NCIt mapping for 2 terms (E082901, E1621).
- Annex F: Added 2 terms (F1006, F1007).
- Annex G: Added 1 term (G07003). Updated NCIt mapping for 1 term (G04094).
March 5, 2021 Update: IMDRF 2021 Maintenance
- Annex A: Modified 2 terms (A0908, A15)
- Annex B: Added 1 new term (B23) and modified 1 term (B16).
- Annex C: Added 1 new term (C23) and modified 1 term (C19).
- Annex D: Added 4 new terms (D0107, D0108, D1501, D18) and modified 3 terms (D10, D1107, D12).
- Annex E: Added 2 new terms (E2120, E2342) and modified 23 terms (E0105, E010904, E0115, E0135, E0304, E0508, E0710, E0749, E082901, E0835, E0843, E1101, E1305, E1409, E1412, E1625, E1904, E1905, E2106, E2119, E231201, E231501, E2336). Updated NCIt mapping for E1001.
- Annex F: Modified 5 terms (F14, F2204, F2305, F25, F26)
- Annex G: Modified 9 terms (G02011, G0201501, G02020, G03006, G0405202, G04095, G04130, G0600102, G0600601). Updated NCIt mapping for G03008 and G04077.